Operating Temperature -40°C~125°C TJ
Moisture Sensitivity Level (MSL) 1 (Unlimited)
Terminal Finish Matte Tin (Sn)
Additional Feature UL RECOGNIZED
Peak Reflow Temperature (Cel) 260
Reach Compliance Code unknown
Time@Peak Reflow Temperature-Max (s) 10
Qualification Status Not Qualified
Max Repetitive Reverse Voltage (Vrrm) 600V
Channel Type Bidirectional
Trigger Device Type ALTERNISTOR TRIAC
Voltage - Gate Trigger (Vgt) (Max) 2V
Current - Non Rep. Surge 50, 60Hz (Itsm) 335A 400A
Leakage Current (Max) 5mA
Critical Rate of Rise of Off-State Voltage-Min 625V/us
Triac Type Alternistor - Snubberless
Critical Rate of Rise of Commutation Voltage-Min 50V/us