Built-in Protections TRANSIENT; OVER CURRENT; OVER VOLTAGE; THERMAL
Drain to Source Resistance 260Ohm
Rds On (Typ) 250m Ω (Max)
Output Peak Current Limit-Nom 1.7A
Fault Protection Current Limiting (Fixed), Over Temperature, Over Voltage
Continuous Drain Current (ID) 7A
Switch Type General Purpose
Voltage - Supply (Vcc/Vdd) Not Required
Output Configuration Low Side
Nominal Supply Current 100μA
Max Power Dissipation 35W
Moisture Sensitivity Level (MSL) 3 (168 Hours)
Series OMNIFET II?, VIPower?
Operating Temperature -40°C~150°C TJ