Operating Temperature 0°C~70°C
Moisture Sensitivity Level (MSL) 2 (1 Year)
Number of Terminations 28
Terminal Finish Matte Tin (Sn)
Additional Feature EXTERNAL CHARGE PUMP; TRISTATABLE RECEIVERS
Subcategory Line Driver or Receivers
Voltage - Supply 4.5V~5.5V
Peak Reflow Temperature (Cel) 260
Time@Peak Reflow Temperature-Max (s) 40
Base Part Number DS14C241
Qualification Status Not Qualified
Output Characteristics TOTEM-POLE
Input Characteristics SCHMITT TRIGGER
Number of Drivers/Receivers 4/5
Receiver Number of Bits 5
Receiver Hysteresis 400mV
Interface Standard EIA-232-E; TIA-232-E; V.28
Receive Delay-Max 6500 ns
Transmit Delay-Max 4000 ns
Output Low Current-Max 0.0032A
High Level Input Current-Max 0.00001A