Operating Temperature 0°C~90°C TJ
Moisture Sensitivity Level (MSL) 3 (168 Hours)
Number of Terminations 256
Terminal Finish Tin/Silver/Copper (Sn95.5Ag4.0Cu0.5)
Subcategory Programmable Logic Devices
Peak Reflow Temperature (Cel) 260
Time@Peak Reflow Temperature-Max (s) 40
Qualification Status Not Qualified
Operating Supply Voltage 1.8V
Programmable Type In System Programmable
Operating Supply Current 3.5mA
Nominal Supply Current 3.5mA
Number of Logic Elements/Cells 24
Output Function MACROCELL
Number of Macro Cells 384
Number of Dedicated Inputs 4
Voltage Supply - Internal 1.65V~1.95V
Delay Time tpd(1) Max 3.5ns