Moisture Sensitivity Level (MSL) 1 (Unlimited)
Max Operating Temperature 175°C
Min Operating Temperature -55°C
Speed Fast Recovery =< 500ns, > 200mA (Io)
Current - Reverse Leakage @ Vr 25μA @ 600V
Voltage - Forward (Vf) (Max) @ If 1.35V @ 35A
Application ULTRA FAST RECOVERY
Max Reverse Voltage (DC) 600V
Average Rectified Current 35A
Reverse Recovery Time 75 ns
Peak Reverse Current 25μA
Max Repetitive Reverse Voltage (Vrrm) 600V
Peak Non-Repetitive Surge Current 500A
Diode Configuration 1 Pair Series Connection