Operating Temperature -40°C~85°C
Moisture Sensitivity Level (MSL) 2 (1 Year)
Number of Terminations 10
Max Power Dissipation 7.2mW
Peak Reflow Temperature (Cel) 260
Time@Peak Reflow Temperature-Max (s) NOT SPECIFIED
Polarity Bipolar, Unipolar
Converter Type ADC, SUCCESSIVE APPROXIMATION
Supply Type Analog, Digital
Voltage - Supply, Analog 2.7V~3.6V
Voltage - Supply, Digital 2.7V~3.6V
Number of Analog In Channels 1
Sampling Rate (Per Second) 1M
Integral Nonlinearity (INL) 3 LSB
Sample and Hold / Track and Hold SAMPLE
Analog Input Voltage-Max 5V
Signal to Noise Ratio (SNR) 100 dB
Analog Input Voltage-Min -2.5V