Operating Temperature -40°C~125°C
Feature Simultaneous Sampling
Moisture Sensitivity Level (MSL) 3 (168 Hours)
Number of Terminations 64
Subcategory Analog to Digital Converters
Max Power Dissipation 298.5mW
Peak Reflow Temperature (Cel) 260
Operating Supply Voltage 5V
Power Dissipation 251.7mW
Converter Type ADC, SUCCESSIVE APPROXIMATION
Supply Type Analog, Digital, Dual, Single
Reference Type External, Internal
Data Interface SPI, Parallel
Voltage - Supply, Analog 5V
Voltage - Supply, Digital 2.7V~3.6V 5V
Number of Analog In Channels 6
Sampling Rate (Per Second) 630k
Output Bit Code 2'S COMPLEMENT BINARY
Integral Nonlinearity (INL) 4 LSB
Sample and Hold / Track and Hold SAMPLE
Number of A/D Converters 1
Output Format SERIAL, PARALLEL, WORD
Signal to Noise Ratio (SNR) 91.5 dB
Max Supply Voltage (DC) 5.5V
Min Supply Voltage (DC) 2.7V
Spurious-free dynamic range (SFDR) 95 dB