Moisture Sensitivity Level (MSL) 3
Number of Terminations 80
Max Operating Temperature 85°C
Min Operating Temperature -40°C
Subcategory Analog to Digital Converters
Peak Reflow Temperature (Cel) 260
Operating Supply Voltage 3.3V
Temperature Grade INDUSTRIAL
Converter Type ADC, PROPRIETARY METHOD
Supply Type Analog, Digital, Single
Number of Analog In Channels 8
Output Bit Code OFFSET BINARY
Linearity Error-Max (EL) 0.0977%
Integral Nonlinearity (INL) 1 LSB
Sample and Hold / Track and Hold SAMPLE
Signal to Noise Ratio (SNR) 61.7 dB
Max Supply Voltage (DC) 3.6V
Differential Nonlinearity 0.5 LSB
Min Supply Voltage (DC) 3V
Spurious-free dynamic range (SFDR) 84 dB