Operating Temperature -40°C~85°C
Moisture Sensitivity Level (MSL) 4 (72 Hours)
Number of Terminations 64
Subcategory Analog to Digital Converters
Max Power Dissipation 600mW
Peak Reflow Temperature (Cel) 260
Operating Supply Voltage 5V
Supply Type Analog, Digital, Dual
Data Interface LVDS - Serial, SPI
Voltage - Supply, Analog 5V
Voltage - Supply, Digital 2.7V~3.3V
Number of Analog In Channels 1
Sampling Rate (Per Second) 4M
Output Bit Code 2'S COMPLEMENT BINARY
Analog Input Voltage-Max 3V
Signal to Noise Ratio (SNR) 92 dB
Max Supply Voltage (DC) 3.15V
Differential Nonlinearity 1 LSB
Min Supply Voltage (DC) 2.85V
Analog Input Voltage-Min -3V
Spurious-free dynamic range (SFDR) 120 dB